ASSEMBLY FITTING INSTRUCTIONS
FOR INSTALLATION OF CMP CABLE
CONNECTOR TYPE TC
FOR TERMINATION OF TRAY CABLES, FLEXIBLE CORD, UNARMOURED AND WIRE BRAID CABLES FOR
USE IN HAZARDOUS LOCATIONS
INCORPORATING EC DECLARATION OF CONFORMITY TO DIRECTIVE 94/9/EC
CMP Document No. FI411 Issue 4 01/13
0518
Registered Office: Glasshouse Street St. Peters Newcastle upon Tyne NE6 1BS
Tel: +44 191 265 7411 Fax: +44 191 265 0581
E-Mail: [email protected] Web: www.cmp-products.com
Notified Body: Sira Certification Service, Rake Lane, Chester CH4 9JN, England.
I, the undersigned, hereby declare that the equipment referred to herein conforms to the requirements of the ATEX Directive 94/9/EC and the
following standards-
EN60079-0:20079, EN60079-1:2007, EN60079-7:2007, BS 6121:1989, EN50262:1998 (Amd 2001), EN61241-0:2006, EN61241-1:2004
Dr Geof Mood - Technical Director - (Authorised Person)
DUBAI HOUSTON NEWCASTLE SINGAPORE SHANGHAI PUSAN PERTH
www.cmp-products.com
Ordering Reference
(Std Thread)
Entry Thread
Min
Thread
Length
Cable Range
Insert
Cable Range
No Insert
Across
Flats
Across
Corners
Assembled
Length
Approx
Weight
Aluminium
(Ozs)
Aluminium NP Brass S. Steel NPT Option Min Max Min Max
TC-050A028 TC-050A028 TC-050A028 1/2” - 0.78
0.13 0.28 - - 1.20 1.30 0.79 1.94
TC-075A028 TC-075A028 TC-075A028 - 3/4” 0.80
TC-050A055 TC-050A055 TC-050A055 1/2” - 0.78
0.26 0.41 0.41 0.55 1.20 1.30 0.79 1.69
TC-075A055 TC-075A055 TC-075A055 - 3/4” 0.80
TC-075A079 TC-075A079 TC-075A079 3/4” - 0.80
0.47 0.61 0.61 0.79 1.48 1.60 0.98 3.17
TC-100A079 TC-100A079 TC-100A079 - 1” 0.98
TC-100A104 TC-100A104 TC-100A104 1” - 1.98
0.67 0.85 0.85 1.04 1.81 1.95 0.98 3.88
TC-125A104 TC-125A104 TC-125A104 - 1-1/4” 1.00
TC-125A127 TC-125A127 TC-125A127 1-1/4” - 1.00
0.92 1.10 1.10 1.27 2.05 2.21 1.18 4.94
TC-150A127 TC-150A127 TC-150A127 - 1-1/2” 1.03
TC-150A150 TC-150A150 TC-150A150 1-1/2” - 1.03
1.22 1.37 1.37 1.50 2.36 2.55 1.26 6.00
TC-200A150 TC-200A150 TC-200A150 2” 1.06
TC-200A174 TC-200A174 TC-200A174 2” - 1.06
- - 1.40 1.74 2.95 3.19 1.26 8.64
TC-250A174 TC-250A174 TC-250A174 - 2” 1.57
TC-200A197 TC-200A197 TC-200A197 2” - 1.06
- - 1.63 1.97 2.95 3.19 1.65 8.29
TC-250A197 TC-250A197 TC-250A197 - 2-1/2” 1.57
TC-250A220 TC-250A220 TC-250A220 2-1/2” - 1.57
- - 1.86 2.20 3.54 3.82 1.65 13.58
TC-300A220 TC-300A220 TC-300A220 - 2-1/2” 1.63
TC-250A244 TC-250A244 TC-250A244 2-1/2” - 1.57
- - 2.13 2.44 3.54 3.82 1.69 13.58
TC-300A244 TC-300A244 TC-300A244 - 3” 1.63
TC-300A268 TC-300A268 TC-300A268 3” - 1.63
- - 2.40 2.68 4.33 4.68 1.69 23.63
TC-350A268 TC-350A268 TC-350A268 - 3-1/2” 1.68
TC-350A315 TC-350A315 TC-350A315 3-1/2” - 1.68
- - 2.62 3.15 4.84 5.23 2.28 34.22
TC-400A315 TC-400A315 TC-400A315 - 4” 1.73
TC-400A354 TC-400A354 TC-400A354 4” - 1.73 - - 2.99 3.54 5.25 5.67 2.28 38.80
All dimensions in inches
Cable Connector Selection Table
Logo’s shown for illustration purposes only. Please check certification for details
CABLE
CABLE
CONNECTOR
CONNECTOR
TYPE
TYPE
TC
TC
TECHNICAL DATA
CABLE GLAND TYPE : TC
INGRESS PROTECTION : IP66, NEMA 4X
PROCESS CONTROL SYSTEM : BS EN ISO 9001
: ISO/IEC 80079-34:2011
HAZARDOUS AREA CLASSIFICATION
ATEX CERTIFICATION No : SIRA 09ATEX1092X
ATEX CERTIFICATION CODE : II 2 GD Exd IIC Gb / Ex e IIC Gb / Ex ta IIIC Da
IEC Ex CERTIFICATION No : IEC Ex SIR.09.0042X
IEC Ex CERTIFICATION CODE : Ex d IIC Gb / Ex e IIC Gb / Ex ta IIIC Da
cCSAus CERTIFICATION No : CSA.09.2220601X
cSAus CERTIFICATION CODE : Class I Div 2 Groups A, B, C, D; Class II, Div 2 Groups E, F, G; Class III Div 2; Enclosure type 4X;
Ex e ; Class I, Zone 1, AEx e
INSTALLATION INSTRUCTIONS
Installation should only be performed by a competent person using the correct tools. Spanners should be used for tightening. Read all instructions
before beginning installation.
SPECIAL CONDITIONS FOR SAFE USE
The glands shall only be fitted to enclosures where temperatures, at the point of mounting, is below 110°C.
The cable shall be effectively clamped as close as possible to the gland.
When used for Ex e (IP54) or Ex ta (IP6X) applications, the user shall provide a suitable interface seal between the gland and associated enclosure
to maintain the level of ingress protection.
Under CEC Code Cable Glands with metric entry threads are only suitable for Areas Classified in ZONES unless fitted with an approved Metric to
NPT thread conversion adaptor. Under NEC Code, cable glands with metric threads can be used in divisions with the following restrictions:
TC Cable Glands will be restricted to Hazardous Location Areas stated under the NEC/CEC Part I, Installation Code under WIRING METHOD.
Gland Size 20S is for use with UL approved tray cable only.
ACCESSORIES
The following accessories are available from CMP Products, as optional extras, to assist with fixing, sealing and earthing :-
Locknut | Earth Tag | Serrated Washer | Entry Thread (I.P.) Sealing Washer | Shroud *
Vue de la page 0
1 2

Résumé du contenu

Page 1 - CONNECTOR TYPE TC

ASSEMBLY FITTING INSTRUCTIONSFOR INSTALLATION OF CMP CABLECONNECTOR TYPE TCFOR TERMINATION OF TRAY CABLES, FLEXIBLE CORD, UNARMOURED AND WIRE BRAID CA

Page 2 - CABLE CONNECTOR COMPONENTS

INSTALLATION INSTRUCTIONS FOR TC CABLE CONNECTORDUBAI • HOUSTON • NEWCASTLE • SINGAPORE • SHANGHAI • PUSAN • PERTHDUBAI • HOUSTON • NEWCASTLE • SINGAP

Commentaires sur ces manuels

Pas de commentaire